Comprehensive DFT Verification and UPF-Based Power Sequencing of an IEEE-754 Division Architecture

Loading...
Thumbnail Image

Journal Title

Journal ISSN

Volume Title

Publisher

Abstract

This project presents the implementation and verification of multiple Design-for-Testability (DFT) and power-aware verification techniques used in modern VLSI systems. The work includes JTAG-based DFT verification using the IEEE 1149.1 TAP controller architecture, scan insertion and Automatic Test Pattern Generation (ATPG) analysis for stuck-at and IDDQ fault models, and Memory Built-In Self-Test (MBIST) verification for memory testing. In addition, UPF-based power-aware verification was performed on an IEEE-754 Dhwajanka floating-point division module to analyze power-domain behavior, signal integrity, and low-power design challenges during power gating. Simulation results validated the functionality, fault coverage, and power-aware behavior of the implemented methodologies. For the IEEE-754 Dhwajanka floating-point division module, the Serial-to-Parallel sub module can be turned OFF for up to 40% of the total time required for a single data transaction. This optimization results in a power saving of up to 61.8% in the Serial-to-Parallel block. Furthermore, the achieved stuck-at and IDDQ ATPG test coverage for the design are 98.78% and 77.45%, respectively.

Description

Project reports and theses published by IIITDM Kancheepuram are protected by copyright. The reproduction or distribution of the content in any format is prohibited without written permission.

Citation

Endorsement

Review

Supplemented By

Referenced By