Comprehensive DFT Verification and UPF-Based Power Sequencing of an IEEE-754 Division Architecture
Loading...
Files
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
This project presents the implementation and verification of multiple Design-for-Testability (DFT) and power-aware verification techniques used in modern VLSI systems. The work includes JTAG-based DFT verification using the IEEE 1149.1 TAP controller architecture, scan insertion and Automatic Test Pattern Generation (ATPG) analysis for stuck-at and IDDQ fault models, and Memory Built-In Self-Test (MBIST) verification for memory testing. In addition, UPF-based power-aware verification was performed on an IEEE-754 Dhwajanka floating-point division module to analyze power-domain behavior, signal integrity, and low-power design challenges during power gating. Simulation results validated the functionality, fault coverage, and power-aware behavior of the implemented methodologies. For the IEEE-754 Dhwajanka floating-point division module, the Serial-to-Parallel sub module can be turned OFF for up to 40% of the total time required for a single data transaction. This optimization results in a power saving of up to 61.8% in the Serial-to-Parallel block. Furthermore, the achieved stuck-at and IDDQ ATPG test coverage for the design are 98.78% and 77.45%, respectively.
Description
Project reports and theses published by IIITDM Kancheepuram are protected by copyright. The reproduction or distribution of the content in any format is prohibited without written permission.